What are the common malfunctions of pure wastewater treatment equipment?

2025-05-12 10:49:08
times

Common faults in pure wastewater treatment equipment include mechanical faults, electrical faults, instrument faults, and process faults. The following are some of the more common types and manifestations of faults:


mechanical failure


Water pump malfunction: Water pumps are commonly used equipment in wastewater treatment, and common malfunctions include impeller wear, seal leakage, and bearing damage. Wear of the impeller can cause a decrease in the flow rate and head of the water pump; Sealing leakage can cause medium leakage, affect the normal operation of equipment, and may even lead to safety accidents; Bearing damage can cause abnormal vibration and noise in the water pump, and in severe cases, it can result in the pump being unable to operate.


Aeration equipment malfunction: Blockage of the aeration head is one of the common problems with aeration equipment, which can lead to uneven aeration and affect the oxygenation and wastewater treatment efficiency. In addition, malfunctions of the aeration fan, such as damaged impeller or belt slippage, can lead to insufficient air flow or unstable air pressure, which can also have adverse effects on the aeration efficiency.


Mixing equipment malfunction: Common malfunctions of mixing equipment include broken mixing shafts, detached or worn mixing blades, and gearbox failures. The breakage of the mixing shaft and the detachment of the blades will cause the mixing function to fail, affecting the mixing effect of wastewater and chemicals; If the gearbox malfunctions, it may cause abnormal mixing speed and fail to meet the process requirements.


electrical fault


Motor failure: The motor is an important driving component of wastewater treatment equipment, and common faults include motor winding short circuit, open circuit, motor overload, overheating, etc. Motor winding faults can cause the motor to fail to start normally or produce abnormal noise and vibration during operation; Overload and overheating can activate the motor protection device, affecting the normal operation of the equipment, and long-term overload may also damage the motor.


Electrical control system failure: The electrical control system includes equipment such as distribution cabinets, PLC controllers, relays, etc. Common faults include damage to electrical components, aging and short circuiting of circuits, program errors, etc. Damage to electrical components can cause equipment to fail to start, stop or control properly; Aging and short circuit of the circuit may cause safety accidents such as electrical fires; Program errors can cause confusion in the operating logic of the device, affecting the normal operation of the entire wastewater treatment system.



Instrument Failure


Flow meter malfunction: Flow meters are used to measure the flow rate of wastewater. Common malfunctions include sensor failure, inaccurate display, etc. Sensor malfunction may result in the inability to measure flow normally or output incorrect signals; Inaccurate display can affect the judgment of wastewater treatment capacity, thereby affecting the adjustment and control of process parameters.


PH meter malfunction: The pH meter is used to monitor the acidity and alkalinity of wastewater. Common problems include electrode aging, inaccurate measurement, and abnormal display. Electrode aging can lead to slower response speed and decreased measurement accuracy; Inaccurate measurement can prevent operators from accurately grasping the pH value of wastewater, thereby affecting the control of treatment processes such as dosing and resulting in poor treatment effectiveness.


Process failure


Excessive water quality: The treated wastewater fails to meet the discharge standards, which may be caused by unreasonable treatment process parameter settings, equipment operation failures, or sudden changes in water quality. For example, insufficient aeration can lead to poor biochemical treatment results, causing indicators such as chemical oxygen demand (COD) and ammonia nitrogen to exceed the standard; Short sedimentation time can result in incomplete removal of suspended solids, leading to turbid effluent.


Sludge swelling: Sludge swelling is a common process failure in the treatment of wastewater using activated sludge method. It is manifested as an increase in sludge volume, deterioration of settling performance, and easy loss with water, which affects the effluent quality. The causes of sludge swelling are complex and may be due to changes in water quality, excessive or insufficient aeration, nutrient imbalances, and other factors.


The above are some common malfunctions of pure wastewater treatment equipment, and other problems may occur during actual operation, which need to be analyzed and treated according to specific situations. Regular equipment maintenance, water quality monitoring, and personnel training can help detect and solve these faults in a timely manner, ensuring the normal operation of wastewater treatment equipment.


  • menu

Address

3rd Floor, Building 1, No. 351 Sizhuan Road, Songjiang District, Shanghai (Headquarters Address)

No. 80 Yu'an West Road, Lai'an County, Chuzhou City, Anhui Province (Factory Address)

+86021-60753686 / +8613162027993

wencheng.sun@longwayhb.com

  • Official Website

    Official Website

  • Exhaust Gas

    Exhaust Gas

  • Effluent

    Effluent

#
Online Service

x